pytests: import test_prefix_shorter_than_header (test1)

parent 9638d51c
"""TCP Connection Management tests"""
import struct
import time
import dns
import dns.message
......@@ -41,3 +43,27 @@ def test_pipelining(kresd_sock):
msg_answer = utils.receive_parse_answer(kresd_sock)
assert msg_answer.id == MSG_ID_SECOND
def test_prefix_shorter_than_header(kresd_sock):
"""
Test prefixes message by the value, which is less then the length of the DNS
message header and sequentially sends it over TCP connection. (RFC1035 4.2.2)
Expected: TCP connection must be closed after `net.tcp_in_idle` milliseconds.
(by default, after about 10s after connection is established)
"""
msg = dns.message.make_query('localhost.', dns.rdatatype.A, dns.rdataclass.IN)
data = msg.to_wire()
datalen = 11 # DNS Header size minus 1
buf = struct.pack("!H", datalen) + data
for _ in range(15):
try:
kresd_sock.sendall(buf)
except BrokenPipeError:
break
else:
time.sleep(1)
else:
assert False, "kresd didn't close connection"